![]() Step 1 Navigate to Network in the Control Panel by clicking Start, selecting Settings, clicking Control Panel, then double-clicking Network.Ī list of installed network components appears. To ensure that the IPX/SPX-compatible protocol is set to the appropriate frame type, follow these steps: Step 9 Close the protocol.ini file and exit the text editor. Table 3-2: NET.CFG and PROTOCOL.INI Frame Formats NET.CFG Format Step 8 If there is no line starting with FRAME=, or if the frame type specified does not match the frame type net.cfg, add the frame type to protocol.ini using the format shown in Table 3-2. (Note that the format of the lines differs slightly, as shown in Table 3-2.) If the frame types are the same, close the file, exit the text editor, and proceed to the next section, " Run the Setup Program." Step 7 If there is a line in the NWLINK section starting with FRAME=, make sure that it specifies the same frame type that you noted in the net.cfg file in Step 2. If there is no NWLINK section, create this section header. If this file does not exist, create it in the Windows directory. This is the file in which NWLINK is configured. Step 4 Note the values you typed in Step 2 and Step 3, and close the file. ![]() If the line is missing, type the line that specifies the IPX frame type used on your network: Step 3 Immediately below the lines displayed in Step 2, find one or more of the following lines. If there are no similar lines, type the line that specifies the Ethernet frame type used on your network. Step 2 Find one or more of the following lines, which configure the IPX/SPX frame type. Step 1 Use a text editor to open the net.cfg file. To ensure that the IPX/SPX frame type and the NWLINK frame type are set to the same value, follow these steps: Mismatched frame types are a common source of problems. These components use different configuration files, but both configuration files must specify the same frame type. On Windows for Workgroups computers, the NWLINK component supplied by Microsoft must interoperate with the IPX/SPX component supplied by Novell. In addition, NWIPXSPX.DLL and NWCALLS.DLL are provided in the NETWARE.DLL subdirectory of the IPeXchange client diskette. If your installed Novell files are outdated, you can download new files from NetWire, CompuServe, or. You can also find it by searching with your web browser. This tool is in a self-extracting file named windr3.exe that is located at Novell's FTP site, /pub/netwire/ To determine the version numbers of your files, you can download the Novell Technical Support (NTS) Windows Diagnostics tool, ntswd.exe. Typically installed in \windows or \windows\system Table 3-1: Required Versions of IPX/SPX Components Component The IPeXchange client relies on the Novell IPX/SPX components and versions listed in Table 3-1. Obtain the WIN32S subsystem from Microsoft. Note You can run 32-bit applications on Windows 3.1 by using a Microsoft 32-bit subsystem. In addition, to ensure smooth installation and startup on a Windows for Workgroups operating system, check the IPX/SPX version numbers and compatibility of configured frame types before installing the IPeXchange client software. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |